Upgrading VCF 5.2 to 9.1: sequence, prechecks and fixes
Upgrade VCF 5.2.x to 9.1 in Broadcom's order: Aria Operations to VCF Operations, SDDC Manager, management services, then vCenter, NSX and ESX.
Going from VCF 5.2 to 9.1 changes who runs lifecycle. In 5.2, SDDC Manager plans and runs every upgrade. In 9.1, VCF Operations does, through a new set of management services and a mandatory License Server. Several Aria products have no 9.1 version at all. Broadcom documents one strict order for this, and its KBs list what breaks when a step runs early. This runbook follows that order for the management domain. Already on 9.0? Use Upgrading VCF 9.0 to 9.1. Every supported path is in the upgrade path matrix.
The question for a 5.2 estate is always the same: can we go straight to 9.1, and what breaks on the way? The short answer is yes from most 5.2 builds, with one trap around 5.2.4. This post walks Broadcom’s documented order, the KB for every known failure, and how I would plan the windows.
How I would plan it
- Check the build first. The single most common surprise in this path is a 5.2.4 or vSphere 8.0 U3j environment that cannot go to 9.1.0. Decide on 9.1.1 or later up front.
- Plan for what disappears. Aria Suite Lifecycle, VMware Identity Manager and Aria Operations for Logs have no 9.1 version. Know who still depends on them before the window, not after.
- Split the work in two. Window one is Aria Operations to VCF Operations, SDDC Manager, the management services and licensing. Window two is vCenter, NSX, ESX and Edge. Only window two touches running infrastructure.
- Move clusters to images early if you can. Baselines are not supported in 9.x, and the transition is easier to test on its own than in the middle of the ESX step.
- Leave workload domains for later. They are Day-N, and a shared NSX instance between two of them has its own trap (see Workload domains).
Can your 5.2 build reach 9.1?
Upgrades are forward-only: the target must be released after your current build (KB 450972). That makes the exact 5.2 build matter.
| Your build | Released | Can go to |
|---|---|---|
| VCF 5.2.0 to 5.2.3 | July 2024 to February 2026 | 9.1.0 and later |
| VCF 5.2.4 (build 25437063) | 27 May 2026 | 9.1.1 and later, not 9.1.0.x |
| VCF 5.2.5 (build 25935019) | 19 November 2026 | Not stated in the Broadcom pages I read; check the Upgrade Planner |
| VCF 5.1.x | Not directly. Move every domain to 5.2.x or 9.0.x first (KB 451166) |
Sources: Broadcom techdocs, KB 450972, KB 448135 and KB 314608.
The rule is easier to see on a timeline. 5.2.4 shipped after 9.1.0, so 9.1.0 counts as going back in time:
Solid green: supported upgradeDashed red: blocked, the target is older than the source
Two more checks:
- vCenter 8.0 U3j and later, ESXi 8.0 U3j and later, and NSX 4.2.4 and later cannot go to 9.1.0.x either. Target 9.1.1.0 or later (KB 448135).
- Aria Operations 8.18.7 cannot go to VCF Operations 9.1.0.x. Go straight to 9.1.1.0 or later (KB 455088).
Run your build through the VCF Upgrade Planner and the Broadcom Interoperability Matrix before you book the window.
The 5.2.x builds
| VCF | SDDC Manager | vCenter | ESXi | NSX |
|---|---|---|---|---|
| 5.2.5 | 25935019 | 8.0 U3m, 25934264 | 8.0 U3m, 25926933 | 4.2.5, 25877985 |
| 5.2.4 | 25437063 | 8.0 U3j, 25413364 | 8.0 U3j, 25429389 | 4.2.4, 25410638 |
| 5.2.3 | 25219033 | 8.0 U3i, 25197330 | 8.0 U3i, 25205845 | 4.2.3.3, 25171318 |
| 5.2.2 | 24936865 | 8.0 U3g, 24853646 | 8.0 U3g, 24859861 | 4.2.3, 24866349 |
| 5.2.1.2 | 24690695 | 8.0 U3c, 24091160 | 8.0 U3b, 24280767 | 4.2.1.0.0, 24304122 |
| 5.2.0 | 24108943 | 8.0 U3a, 24091160 | 8.0 U3, 24022510 | 4.2.0.0.0, 24105817 |
Source: KB 314608. It lists the same vCenter build, 24091160, for 8.0 U3a and 8.0 U3c.
The 9.1.x targets
| Component | 9.1.0.0 | 9.1.1.0 | 9.1.2.0 |
|---|---|---|---|
| SDDC Manager | 25371088 | 25713928 | 25936686 |
| vCenter | 25370922 | 25712839 | 25946533 |
| ESX | 25370933 | 25714478 | 25946735 |
| NSX | 25318225 | 25691509 | 25929667 |
| VCF Operations | 25346025 | 25679751 | 25946717 |
| VCF Automation | 25370929 | 25714559 | 25941159 |
| License server | 25346031 | 25679819 | 25946723 |
Source: the Bill of Materials page of each release in Broadcom techdocs.
What changes from 5.2 to 9.1
BeforeVCF 5.2.x
- SDDC ManagerPlans and runs every upgrade.
- Aria Operations
- Aria Suite LifecycleNo upgrade pathNot upgraded to 9.1. Keep it while VCF Automation still signs in through VMware Identity Manager 3.3.x.
- VMware Identity ManagerNo upgrade path
- Aria Automation
- Aria Operations for LogsNo upgrade pathDeploy Log management as a Day-N task instead.
AfterVCF 9.1.x
- SDDC ManagerChangedIts UI runs only its own upgrade. Domain upgrades move to VCF Operations.
- VCF OperationsChangedUpgraded from Aria Operations with a PAK file. Runs lifecycle from Build > Lifecycle.
- VCF Management ServicesNewFleet Lifecycle, SDDC Lifecycle, software depot, identity broker, Salt, telemetry, on a common runtime.
- License ServerNewMandatory. Needs A and PTR records.
- VCF AutomationChangedUpgraded from Aria Automation.
What else changes:
- vSphere Lifecycle Manager baselines are not supported. Every cluster moves to images during the upgrade.
- vCenter and NSX Manager upgrade in one step, and NSX Edge clusters separately afterwards.
- NSX security needs a vDefend license. NSX security licenses from before 9 are not supported; without a valid license the security features run in 90-day evaluation mode.
- Downloads. The old Offline Bundle Transfer Utility does not work with SDDC Manager 9.x. Use the VCF Download Tool (KB 447995).
Upgrade sequence
The order below is from the Broadcom 9.1 upgrade documentation, section “From VCF 5.2.x”. Skip the products you do not run. Workload domains are a Day-N task.
Phase 1Fleet management
Aria Operations always goes first. Upgrade the other products only where they are installed.
- Aria Operations and cloud proxies to VCF Operations 9.1Aria Operations admin UI, PAK file
- vSphere Replication and Avi Load Balancer, if installed
- SDDC ManagerSDDC Manager UI > Workload Domains > management domain > Updates
- VCF Management Services and License ServerVCF Operations > Build > Lifecycle
- Aria Automation to VCF Automation, Orchestrator, Operations for Networks, HCXIf installed
Phase 2Management domain core
Everything here runs from the domain's Upgrades tab in VCF Operations, except the vSAN format.
- Plan the domain upgrade and run prechecksBuild > Lifecycle > VCF Instances > domain > Upgrades
- NSX Global Manager, in a federation
- vCenter and NSX ManagerOptimized window or sequential
- Move clusters from baselines to imagesPowerShell script or SDDC Manager API
- vSphere Kubernetes Service and Supervisor, if used
- vSAN witness host, then ESXUpgrades > VMware ESX Upgrade
- NSX Edge clusters and NSX finalizeUpgrades > NSX Edge Clusters Upgrade and NSX Upgrade Finalize
- vSphere Distributed Switch, VMware Tools, VM compatibility
- vSAN on-disk format and vSAN File ServicevSphere Client
- Apply VCF Configuration Upgrades
Phase 3Workload domains
Day-N. Upgrade them later.
- Plan, precheck, then the same core orderVCF Operations
Before you start
The upgrade resets out-of-the-box content in VCF Operations to defaults, including alerts, symptoms, dashboards, views and reports. Back up anything you changed.
Steps
Upgrade Aria Operations to VCF Operations 9.1
Download the VCF Operations 9.1 PAK file and upload it in the Aria Operations administration interface (Software Update, Install a Software Update). Cloud proxies upgrade on their own afterwards, up to 10 at a time. The primary VCF Instance needs a cloud proxy; deploy one after the upgrade if it has none.
Afterwards, remove VCF Operations from Aria Suite Lifecycle 8.x without deleting the VM. Keep Aria Suite Lifecycle and VMware Identity Manager 3.3.x running while VCF Automation still uses them to sign in.
Failed resource key=pak_manager.action_failed, resource args=[run master postgres db upgrade]Revert the node snapshots, run the validation script from KB 440200, then install the update again.
Upgrade SDDC Manager
On 5.2.x this still runs in the SDDC Manager UI. Go to Workload Domains, open the management domain, then the Updates tab. Under Available Updates, click Plan Upgrade, pick the 9.1 target and click Next. Select the version on Change Summary, Confirm, then Update Now or Schedule Update.
Check first that your Avi Load Balancer version is compatible with the target. In an air-gapped setup, download the SDDC Manager binary with the VCF Download Tool.
After the upgrade, open Administration > Depot Settings. The online depot now signs in with an activation code from the VCF Business Services console, not a download token.
Triggering SDDC Manager upgrade bundle failed. A problem has occurred on the server.Fixed in SDDC Manager 9.1.1. On 9.1.0, start the prechecks from the domain’s Upgrades tab instead (KB 458822).
This version is incompatible with the current environment.5.2.4.0 cannot go to 9.1.0.x. Pick 9.1.1 or later (KB 447234).
vSphere SHA-1 validation failed. High: Do not perform upgrade without addressing this issue.The check can fail even when the backend validation passed. Restart the operations manager service on SDDC Manager and retry (KB 453459).
systemctl restart operationsmanagerDeploy VCF Management Services and the License Server
VCF Operations and SDDC Manager must both be on 9.1. In VCF Operations, open Build > Lifecycle, expand VCF Instances and select the instance. Open the SDDC Manager Upgrades tab, then Install Management Services. Click Next steps, then Install, and in the Components Installation dialog click Connect, then Install.
The wizard needs at least 12 IPs (a /28; 30 recommended), lowercase FQDNs with forward and reverse DNS, no .local domain, an IPv4 FQDN for the License Server, and an internal CIDR that does not overlap your networks (default 198.18.0.0/15, or 240.0.0.0/15 or 250.0.0.0/15). Remove any SSL-terminating proxy in front of VCF Operations first. Do not Storage vMotion these VMs or move them to another folder or resource pool afterwards.
The API path needs the SHA-256 thumbprint of VCF Operations:
echo | openssl s_client -connect <vcfoperations-fqdn>:443 2>/dev/null | openssl x509 -noout -fingerprint -sha2569.1 validates certificates strictly. A certificate that lists only an IP address, or misses node FQDNs in its Subject Alternative Name, makes the inventory migration into Fleet Lifecycle fail and blocks the upgrade. Replace those with CA-signed certificates whose SAN lists every node before you start (KB 449907).
Failed to complete the registration. Please try again. If this error persists, contact support.Your DNS or IPs sit in 172.17.0.0/16 and clash with the server’s Docker network. Deploy License Server 9.1.0.0200 (build 25499768) or later (KB 441526).
Register and license
Coming from 5.2.x, register VCF Operations and the License Server with the VCF Business Services console, then assign the licenses. The License Server needs A and PTR records, and vCenter must resolve its name; most of the licensing KBs below come down to DNS or time.
One or more vCenter instances are not connected to a license server.The License Server is not deployed or not registered yet. Register it and assign the licenses (KB 440471).
vCenter is not able to resolve the hostname of license server.Upgrade the other management products
Upgrade Aria Automation to VCF Automation 9.1, then Aria Automation Orchestrator, Aria Operations for Networks and VMware HCX, where you run them. Aria Operations for Logs has no upgrade path; deploy Log management as a Day-N task.
Step vmsp_upgrade_vcfa failed.The upgrade failed at the Power Off Source Cluster step. Follow KB 441260.
Plan the domain upgrade and run prechecks
From here on, VCF Operations runs the upgrade. Open Build > Lifecycle > VCF Instances, select the management domain and open the Upgrades tab. Click Plan Domain Upgrade and work through Target Version, Customize Target Version, vCenter and NSX Upgrade Options and Plan Overview, then Submit Plan.
Then go to Prechecks, choose Run Prechecks for the target version, and open View Details. You can filter by Errors and Warnings and export the full report.
vCenter backup should not be located on SDDC ManagerPoint the vCenter file-based backup to an external SFTP, FTP, HTTP or NFS target in the VAMI (port 5480, Backup), run a backup, then rerun the precheck (KB 448668).
Resource validation timeoutTake an SDDC Manager snapshot, then set the NSX Manager status from ACTIVATING to ACTIVE through the inventory API (KB 457342).
If the Enter Maintenance Mode precheck fails because of pinned VMs, but the host can enter maintenance mode in vCenter, Broadcom documents a way to suppress the dry-run check. Add these two lines to /opt/vmware/vcf/lcm/lcm-app/conf/application-prod.properties on SDDC Manager, then restart the service:
lcm.nsxt.suppress.dry.run.emm.check=truelcm.esx.suppress.dry.run.emm.check.failures=truesystemctl restart lcmUpgrade vCenter and NSX Manager
In a federation, upgrade the NSX Global Manager first. Then pick one of two ways on the Upgrades tab:
- Optimized maintenance window. VMware vCenter Preparation Stage builds the new vCenter while the old one stays online (Configure, Run Prechecks, then Schedule with automatic or manual switchover). Then VMware NSX Manager Nodes Upgrade. Then VMware vCenter Switchover Stage, Switchover Now. Broadcom puts the switchover at about 5 minutes under ideal conditions.
- Sequential. VMware NSX Manager Nodes Upgrade first, then VMware vCenter Upgrade. From 5.2.x only the reduced downtime upgrade is offered.
Each vCenter needs one spare IP on the management subnet. The vCenter target must match the SDDC Manager version. If the switchover fails before it completes, it rolls back on its own; after that, restore the file-based backup.
Set DRS back to the automation level you wrote down once this step is done.
Cannot upgrade to VCF version 9.1.0.0 for domain [Domain-ID] in a compatible way.vCenter 8.0 U3j, ESXi 8.0 U3j or NSX 4.2.4 or later is newer than 9.1.0. Target 9.1.1.0 or later (KB 448135).
Some uplink distributed portgroup(s) on the source vCenter Server have NetFlow enabled.Upgrade Aria Operations for Networks first, or clear “Enable NetFlow (IPFIX) on this vCenter” in Operate > Administration > Integrations (KB 441813).
Unable to get vCenter upgrade statusReboot the vCenter appliance, clear the bundle from its update repository and download it again, or run a regular upgrade instead of the reduced downtime one (KB 450414).
Move clusters from baselines to images
vSphere Lifecycle Manager baselines are not supported from VCF 9.0. Move every cluster to an image with Broadcom’s PowerShell script (menu-driven or command line) or the SDDC Manager API, after SDDC Manager is on 9.1. If a cluster runs Supervisor, or the move is not possible earlier, do it after the vCenter upgrade and before ESX.
Upgrade ESX
In a stretched cluster, upgrade a physical vSAN witness host by hand first. In Build > Lifecycle, open the instance, then Image Management > Import Image. On the domain’s Upgrades tab, choose VMware ESX Upgrade, Configure, Run Prechecks, then Upgrade Now or Schedule. The image ESX version must match the Bill of Materials of your target, for example build 25946735 for 9.1.2.0.
Wait about 15 minutes after each upgrade before you schedule the next one, so the inventory can reconcile.
Upgrade NSX Edge and finalize NSX
On the Upgrades tab, choose VMware NSX Edge Clusters Upgrade and NSX Upgrade Finalize, then Configure, Run Prechecks and Upgrade Now or Schedule. Broadcom’s page does not state the downtime for this step.
Finish the vSphere and vSAN side
Upgrade the vSphere Distributed Switch, VMware Tools and VM compatibility. Once ESX and vCenter are done, every disk is healthy, no host is in maintenance mode and nothing is rebuilding, open the vSAN cluster in the vSphere Client: Configure > vSAN > Disk Management, Pre-check Upgrade, then Upgrade. Upgrade vSAN File Service if you use it, and finish with Apply VCF Configuration Upgrades.
Workload domains
Workload domains can wait. Upgrade each one later from VCF Operations with the same plan, precheck and core order.
If two workload domains share one NSX instance, both must have vCenter and ESX at the target before the NSX host transport nodes upgrade, or the upgrade stops at the NSX Edge stage (KB 445682).
Verify
- In VCF Operations, In-Progress Upgrades > View Status shows every task with a green check and the status Upgraded.
- Every management domain component reports the target version in Build > Lifecycle.
- Every vCenter is connected to the License Server, with no license banner in VCF Operations.
- DRS is back on its original automation level.
- Delete the Aria Operations node snapshots and the SDDC Manager snapshot once you are satisfied.
Gotchas
- Keep the order. If SDDC Manager reaches 9.1 while NSX is still on 4.2, the NSX pre-upgrade bundle goes missing (KB 447995).
- In VCF Operations, run prechecks per component, not with Run Prechecks (ALL) (VCF Operations 9.1 known issues).
- The Log management precheck is not supported for 9.x to 9.1 upgrades. Ignore it and proceed (VCF Operations 9.1 known issues).
Rollback
Broadcom’s prerequisites ask for a cold snapshot of SDDC Manager, snapshots of the Aria Operations nodes, and backups of every vCenter and NSX Manager. The vCenter switchover rolls back on its own if it fails before it completes; after that, the way back is the file-based vCenter backup.